Elija sus visitas especiales
Centro de información
Solución
Productos recomendados
Últimas noticias
Póngase en contacto con nosotros

Válvula de presión residual

Válvula de presión residual

The residual pressure valve is a device set up to maintain a certain indoor static pressure and realize the energy-free automatic control of the positive pressure in the air-conditioned room.

Detalles del producto

The residual pressure valve is a one-way air volume regulating device. The opening degree is adjusted according to the static pressure difference, and the position of the weight is used to balance the wind pressure. The air volume passing through the residual pressure valve is generally between 100-1200m3/h, and the pressure difference is maintained between 5-40Pa.

Características del producto

1. Tight closing, sensitive response

2. Easy to adjust, beautiful appearance

3. No energy consumption

4. Exhaust wind speed does not affect the indoor air flow state 5. The position of the weight can be adjusted according to the requirements of air volume, pressure difference, and temperature (such as 70℃)

Working principle:

When the air pressure in the clean room exceeds the standard air pressure, the pressure reducing valve automatically opens. When it is lower than the standard air pressure, the valve returns to the closed state, thereby balancing the air pressure. This prevents noise and possible explosions caused by the squeezing of air pressure in the clean room. There are many types of residual pressure valves, and different applications have subtle differences. Please call us for detailed information on residual pressure valves.

ESPECIFICACIÓN DEL PRODUCTO:

Size(L×W×D mm) 465×265×212
Residual Pressure(Pa) 5 10 15 20 25
Exhaust volume(m3/h) 115 270 410 480 560

Structural features:

1. The residual pressure valve is a wall-mounted structure.

2. The residual pressure valve box is made of high-quality cold-rolled steel plate, which is bent and welded. The surface is rust-proofed and then painted, which is beautiful and durable.

3. The structure is simple, light and flexible; the appearance is beautiful and easy to install.

4. The position of the weight can be adjusted according to the air volume and pressure difference.

5. The valve plate is made of aluminum plate, which is light and stainless.

6. The valve plate adopts a rolling bearing support structure, which is flexible to open.

Installation:

1. Please choose a wall structure that can bear the weight of the residual pressure valve. When the wall does not have sufficient support capacity, the clean room or cannot stably support the residual pressure valve, please add an auxiliary support structure.

2. The residual pressure valve should be installed horizontally and vertically to avoid tilting to avoid deformation of the box and other faults.

3. For newly installed or long-unused residual pressure valves, they must be carefully cleaned with a vacuum cleaner or dust-free tools before use.

4. The thickness of the wall where the residual pressure valve is installed should be within the range of 30 to 50 mm.

Use:

1. Please use this product in a dust-free and wet place. This product is for indoor use, please do not use it outdoors.

2. Please do not wipe the body with volatile oil, thinner, etc. to avoid damaging the paint layer or causing discoloration.

3. Please choose a floor or wall structure that can bear the weight of this product.

4. If this product is installed in a tilted state, it will cause failures such as deformation of the box. 5. It is prohibited to use it in the following places: low temperature, high temperature, high humidity, condensation, dust, and places with oil smoke and fog.

5. Environmental conditions for use: Temperature: 5℃~40℃ Relative humidity: not more than 85% (at 35℃)

6. When transporting and storing in a clean room, there must be no strong impact, and it must not be directly in a water spray or splashing environment to avoid damage and rust.

Maintenance:

1. According to the cleanliness of the environment, clean the outer surface of the residual pressure valve with a dust-free cloth regularly (usually once a week).

2. Keep clean and avoid collision.

Aplicaciones:

The residual pressure valve has good adaptability to rapid static pressure changes. It is generally recommended to be installed on the outer wall on the downwind side between clean rooms with different static pressure differences, and should not be installed in places that obviously affect the indoor airflow on the downstream side. When the smoke-proof stairwell is pressurized and the front room is not supplied with air, a residual pressure valve may also be installed on the partition wall between the stairwell and the front room. The device consists of an outer frame, a valve plate and a counterweight. The maximum opening angle of the valve plate is 45°. It can be widely used in clean workshops or clean rooms to maintain a positive pressure difference between indoors and outdoors, so that excess indoor air can be discharged and outdoor air can be prevented from invading.

Dejar un mensaje
询盘表单
Productos relacionados