{"id":5912,"date":"2026-08-26T10:58:48","date_gmt":"2026-08-26T02:58:48","guid":{"rendered":"https:\/\/www.bacintl.com\/?p=5912"},"modified":"2026-08-26T08:35:43","modified_gmt":"2026-08-26T00:35:43","slug":"gmp%e2%80%91compliant-operation-specifications-parameter-settings-and-on%e2%80%91site-inspection-key-points-for-spray-disinfection-air-shower","status":"publish","type":"post","link":"https:\/\/www.bacintl.com\/fr\/gmp\u2011compliant-operation-specifications-parameter-settings-and-on\u2011site-inspection-key-points-for-spray-disinfection-air-shower\/","title":{"rendered":"GMP\u2011Compliant Operation Specifications, Parameter Settings and On\u2011Site Inspection Key Points for Spray Disinfection Air Shower"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-5913\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35-1000x562.jpg 1000w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-35.jpg 1248w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p><strong>1. Standard Parameter Settings<\/strong><\/p>\n<ul>\n<li>\n<p>For high\u2011grade aseptic pharmaceutical scenarios: Air\u2011shower duration 15\u201120\u202fs, spray disinfection duration 15\u202fs, stable air velocity 25\u201130\u202fm\/s, medium\u2011high atomization concentration, to guarantee thorough dust removal and sterilization.<\/p>\n<\/li>\n<li>\n<p>For general\u2011grade aseptic scenarios in food and cosmetics industries: Air\u2011shower duration 10\u201115\u202fs, spray disinfection duration 10\u202fs, moderate atomization concentration, balancing cleanliness and operational efficiency.<\/p>\n<\/li>\n<li>\n<p>For scenarios with frequent personnel access: Intermittent disinfection mode can be enabled to prevent excessive mist accumulation caused by over\u2011disinfection. All configured parameters shall be archived. Frequent arbitrary modification is prohibited.<\/p>\n<\/li>\n<\/ul>\n<p><strong>2. Standard Operating Procedures<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-5914\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36-1000x562.jpg 1000w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-36.jpg 1248w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p>Before entering the clean area, personnel shall wear complete cleanroom suits, face masks and gloves. After entering the air\u2011shower chamber, close both inner and outer doors. The unit starts automatically via sensor to perform air\u2011blow dust removal together with atomization disinfection. Personnel are allowed to enter the clean workshop only after disinfection finishes and mist is fully exhausted. Overcrowding inside the chamber, door\u2011open blowing operation and skipping disinfection procedure are strictly forbidden to eliminate compliance loopholes.<\/p>\n<p><strong>3. Key Points for GMP On\u2011Site Inspection<\/strong><\/p>\n<p>Regulatory inspectors focus on the following items: normal function of interlocked double doors, qualified air\u2011shower velocity, valid spray disinfection performance, compliant disinfectant selection, complete equipment operation logs, clean chamber interior free of dust and water accumulation, and unclogged nozzles. Enterprises shall maintain intact equipment functions, compliant parameters and full records without non\u2011compliant operations.<\/p>\n<p><strong>4. Compliant Ledger &amp; Documentation Management<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-5915\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37-1000x562.jpg 1000w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/08\/\u82f1\u6587\u6d77\u62a5-37.jpg 1248w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p>The following records shall be established: equipment operation log, disinfectant replacement log, filter\u2011element replacement log, equipment maintenance &amp; calibration log. All usage, maintenance and replacement activities shall be traceable to meet requirements for routine GMP inspections.<\/p>","protected":false},"excerpt":{"rendered":"<p>The operation specifications, parameter configuration and daily management of spray disinfection air showers directly determine the microbial\u2011control performance of clean workshops and the pass rate during GMP inspections. Combined with the latest GMP inspection standards, this article defines standardized operating procedures, parameter benchmarks, daily management requirements and documentation for inspection reference, supporting enterprises to achieve compliant equipment implementation.<\/p>","protected":false},"author":3,"featured_media":5913,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[92],"tags":[],"class_list":["post-5912","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/comments?post=5912"}],"version-history":[{"count":1,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5912\/revisions"}],"predecessor-version":[{"id":5916,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5912\/revisions\/5916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/media\/5913"}],"wp:attachment":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/media?parent=5912"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/categories?post=5912"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/tags?post=5912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}