{"id":5633,"date":"2026-07-20T14:37:18","date_gmt":"2026-07-20T06:37:18","guid":{"rendered":"https:\/\/www.bacintl.com\/?p=5633"},"modified":"2026-07-20T08:46:09","modified_gmt":"2026-07-20T00:46:09","slug":"can-the-wind-shower-time-and-wind-speed-of-the-automatic-door-air-shower-room-be-adjusted","status":"publish","type":"post","link":"https:\/\/www.bacintl.com\/fr\/can-the-wind-shower-time-and-wind-speed-of-the-automatic-door-air-shower-room-be-adjusted\/","title":{"rendered":"Can the wind shower time and wind speed of the automatic door air shower room be adjusted?"},"content":{"rendered":"<p>Automatic Door Air Shower Room: Wind Speed and Air Shower Duration Adjustment Instructions<br \/>\n1. Air Shower Duration: All supported adjustable<br \/>\nAdjustment Range<br \/>\nStandard control system setting range: 0 &#8211; 99 seconds. Factory default: 10 seconds\/15 seconds. Pharmaceutical factories and high-cleanliness workshops often set to 20\u201330 seconds.<br \/>\nAdjustment Method<br \/>\nBasic model: Panel buttons and digital display for setting;<br \/>\nHigh-end automatic door air shower: 7-inch touch screen for direct digital input;<br \/>\nLogical Limitation<br \/>\nThe air shower will be executed only when the front and rear doors are interlocked. The door will unlock automatically when the time is up; You can stop the air shower by pressing the emergency stop at any time.<br \/>\nIndustry Reference<br \/>\nElectronic workshop: 10\u201315 seconds; Pharmaceutical GMP workshop: 20\u201330 seconds; Raw material workshop with heavy dust: 30\u201340 seconds.<br \/>\n2. Air Shower Wind Speed: There are two types of models, and the ability to adjust varies<br \/>\n1. Ordinary fixed-frequency fan model (market basic stainless steel air shower)<br \/>\nWind speed cannot be adjusted continuously<br \/>\nFan power is fixed, the standard wind speed at the nozzle outlet maintains 22\u201328 m\/s (national standard requirement \u2265 25 m\/s);<br \/>\nOnly two modes: full fan on air shower \/ shutdown, cannot adjust fast or slow.<br \/>\n2. Variable-frequency fan model (high-end automatic door \/ AGV dedicated air shower, recommended for high cleanliness scenarios)<br \/>\nWind speed is continuously adjustable<br \/>\nThe control cabinet has a built-in frequency converter, and the fan frequency can be adjusted through the touch screen, and the corresponding nozzle wind speed can be freely set in the 15\u201330 m\/s range;<br \/>\nApplication scenarios:<br \/>\nFor thin and easily scratched materials, lower wind speed (18\u201322 m\/s) is recommended;<br \/>\nFor heavy dust and metal parts, set to 25\u201328 m\/s to meet ISO14644 and GMP dust removal standards.<br \/>\n3. Supplementary Key Standard Requirements<br \/>\nNational standard mandatory for clean air shower rooms: Effective wind speed at the nozzle \u2265 25 m\/s. If the wind speed is lowered below this value, the dust removal effect will significantly decrease, and GMP review will not pass;<br \/>\nVariable-frequency models can only be temporarily lowered when the materials are fragile, and in regular production, it is recommended to maintain above 25 m\/s.<br \/>\n4. Summary<br \/>\nAir shower duration: All automatic door air shower rooms can be freely adjusted from 0 to 99 seconds;<br \/>\nWind speed: Fixed-frequency models cannot be adjusted; Variable-frequency models support continuous speed adjustment, and the variable-frequency system can be selected as needed.<\/p>","protected":false},"excerpt":{"rendered":"<p>Automatic Door Air Shower Room: Wind Speed and Air Shower Duration Adjustment Instructions 1. Air Shower Duration: All supported adjustable Adjustment Range Standard control system setting range: 0 &#8211; 99 seconds. Factory default: 10 seconds\/15 seconds. Pharmaceutical factories and high-cleanliness workshops often set to 20\u201330 seconds. Adjustment Method Basic model: Panel buttons and digital display [&hellip;]<\/p>","protected":false},"author":12,"featured_media":5014,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[92],"tags":[],"class_list":["post-5633","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/comments?post=5633"}],"version-history":[{"count":1,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5633\/revisions"}],"predecessor-version":[{"id":5634,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/posts\/5633\/revisions\/5634"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/media\/5014"}],"wp:attachment":[{"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/media?parent=5633"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/categories?post=5633"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bacintl.com\/fr\/wp-json\/wp\/v2\/tags?post=5633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}