{"id":6693,"date":"2026-11-26T15:36:45","date_gmt":"2026-11-26T07:36:45","guid":{"rendered":"https:\/\/www.bacintl.com\/?p=6693"},"modified":"2026-11-26T08:22:35","modified_gmt":"2026-11-26T00:22:35","slug":"working-principle-of-clean-booth-ffu-air-supply-and-curtain-isolation-purification","status":"publish","type":"post","link":"https:\/\/www.bacintl.com\/es\/working-principle-of-clean-booth-ffu-air-supply-and-curtain-isolation-purification\/","title":{"rendered":"Working Principle of Clean Booth: FFU Air Supply and Curtain Isolation Purification"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-6694\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Working-Principle-of-Clean-Booth-2-1000x562.jpg 1000w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p>1. Overall Working Logic<\/p>\n<p>The clean booth adopts vertical unidirectional airflow supplied by FFUs installed on the top. Soft curtains or hard enclosures around form a relatively enclosed isolation space, with return air passages reserved at the bottom or surrounding sides. Each FFU comes with a built-in fan. Air is drawn in from the top of the FFU, filtered by its internal HEPA filter, and delivered downward as uniform vertical airflow to cover the operating zone inside the booth. Dust and aerosols generated by operators and equipment inside the booth are carried downward by the unidirectional airflow, flow out from the return air opening at the lower part of the booth, and circulate back to the air inlet of FFUs for continuous recirculation. Pollutants are constantly diluted and removed to maintain the cleanliness level inside the booth. It can stably achieve ISO5\uff5eISO7 (Class 100, Class 1000, Class 10000) in most applications, widely used for electronic assembly, optical inspection, small package filling, sample testing and other working stations requiring local high cleanliness.<\/p>\n<p>2. FFU Air Supply: Core Power and Filtration Unit of Clean Booth<\/p>\n<p>FFU is the core air supply component of the clean booth, equipped with a centrifugal fan and HEPA filter. H14 HEPA filters are commonly adopted, while U15 ULPA filters are selected for stringent projects. The fan draws air above the booth, which first passes through the pre-filter of FFU for coarse particle interception, then goes into the main HEPA filter to remove submicron particles and attached microorganisms. Filtered clean air is sent downward to form vertical laminar flow. The key control parameter is face velocity, normally maintained at 0.36\uff5e0.5 m\/s. If the velocity is too low, the airflow is vulnerable to disturbance. Operator movement and heat dissipation airflow can disrupt the laminar flow and cause dust to float and accumulate. If the velocity is excessively high, noise and energy consumption will rise, and settled dust on the ground may be re-suspended to trigger secondary dust pollution. When multiple FFUs are assembled side by side, synchronous commissioning is required to ensure uniform airflow velocity across the entire top air outlet surface and avoid high-speed zones or dead zones with no airflow. FFUs support individual start-stop and group control for convenient maintenance. Failure of a single FFU will not directly disable the whole clean booth.<\/p>\n<p>3. Curtain Isolation: Block External Contamination and Stabilize Airflow Boundary<\/p>\n<p>The isolation curtain serves as the barrier of the clean booth. Anti-static PVC soft curtains are the mainstream option, and acrylic or stainless steel hard enclosures are available as alternatives. The curtain is not designed for full airtight sealing. Its function is to reduce intrusion of external turbulent flow and prevent low-cleanliness air outside the booth from rushing directly into the protected zone. A clean booth is relatively isolated instead of an airtight chamber. A return air gap is reserved at the bottom of the curtain for smooth airflow circulation inside the booth. Damaged curtains or frequent wide opening will lead to massive infiltration of dusty outside air, and the cleanliness level inside the booth will drop rapidly. Anti-static curtains can restrain static accumulation, suitable for lithium battery, microelectronics and optical component industries sensitive to static electricity. Some high-spec clean booths are equipped with air curtains at openings to form an airflow barrier and further reduce external air infiltration. Standard models can meet requirements simply with isolation curtains and unidirectional laminar flow.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-6695\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Air-Circulation-Path-of-Clean-Booth-1000x562.jpg 1000w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p>4. Complete Air Circulation Path<\/p>\n<p>Full airflow sequence: Air above the booth is sucked by FFU fan \u2192 Pre-filtration \u2192 H14 HEPA filtration \u2192 Vertical downward delivery into the protected zone inside booth \u2192 Carry away dust and aerosols generated at the working station \u2192 Flow out from the gap under the curtain at the booth bottom \u2192 Air outside the booth re-enters the FFU air inlet for continuous circulation. This system runs on internal recirculation and is mostly without fresh air intake. If the workshop has extremely high background dust concentration, particle concentration inside the booth will gradually rise after long-time operation. Fresh air supplement modules can be added for such scenarios.<\/p>\n<p>5. Structural Configuration and Key Selection Points<\/p>\n<p>The frame is assembled with aluminum alloy profiles for easy disassembly. The length and width can be adjusted according to workstation size, and the booth can be relocated and reassembled later. There are two main return air types:<\/p>\n<ol>\n<li>\n<p>Natural return air: Air returns through gaps under soft curtains, simple structure and low cost, the most widely used type.<\/p>\n<\/li>\n<li>\n<p>Negative pressure return air with return grille and plenum chamber: More stable airflow, adopted for high-grade and heavy dust-generating working stations. Monitoring accessories generally include differential pressure gauges and air velocity sensors to monitor FFU operating status. When filter resistance rises due to dust accumulation, the air velocity drops to remind timely filter replacement.<\/p>\n<\/li>\n<\/ol>\n<p>6. Application Scope and Common Misconceptions<\/p>\n<ol>\n<li>\n<p>A clean booth is local purification equipment. It cannot upgrade the cleanliness level of the whole workshop. Only the space inside the booth is protected, and the area outside remains at its original cleanliness class.<\/p>\n<\/li>\n<li>\n<p>Clean booth is not equivalent to Grade A laminar flow. Open soft-curtain clean booth has weak anti-disturbance capacity and is generally not applied for GMP Grade A aseptic filling. Hard-enclosed booth combined with laminar flow ceiling is preferred for high-risk aseptic scenarios.<\/p>\n<\/li>\n<li>\n<p>Insufficient FFU quantity leads to inadequate air supply area and low airflow velocity. Determine the effective internal working area first during selection, then calculate the required FFU quantity to achieve full coverage.<\/p>\n<\/li>\n<li>\n<p>Static control cannot be ignored. Anti-static curtains must be selected for microelectronics and lithium battery industries; ordinary PVC curtains tend to accumulate static electricity and damage electronic components.<\/p>\n<\/li>\n<li>\n<p>Long-term open status or unreplaced damaged curtains will invalidate isolation, making the clean booth useless.<\/p>\n<\/li>\n<\/ol>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-6696\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-767x431.jpg\" alt=\"\" width=\"767\" height=\"431\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/11\/Selection-Guide-Common-Misconceptions-1000x562.jpg 1000w\" sizes=\"(max-width: 767px) 100vw, 767px\" \/><\/p>\n<p>Daily Maintenance Tips<\/p>\n<ul>\n<li>\n<p>Regularly check FFU running noise and air velocity<\/p>\n<\/li>\n<li>\n<p>Monitor filter differential pressure and replace filters once reaching final resistance<\/p>\n<\/li>\n<li>\n<p>Wipe curtains and frames periodically to reduce surface dust accumulation<\/p>\n<\/li>\n<li>\n<p>Minimize large-amplitude opening of curtains during operation<\/p>\n<\/li>\n<\/ul>\n<p>Conclusion<\/p>\n<p>The <a href=\"https:\/\/www.bacintl.com\/es\/clean-booth\/\">clean booth<\/a> delivers vertical unidirectional clean airflow via top-mounted FFUs, forms isolation boundaries with surrounding curtains, and continuously removes pollutants generated at workstations through internal air circulation. It creates a local high-cleanliness area in ordinary workshops with low cost. Its core advantages are modular design, easy disassembly, no need for air duct and ceiling renovation, and flexible adaptation to frequently changed production processes. Stable clean environment inside the booth can be maintained only by matching cleanliness grade, controlling face velocity, and strengthening curtain protection and static management during selection.<\/p>","protected":false},"excerpt":{"rendered":"<p>Clean booth, also known as clean tent, is a flexible modular local clean unit. With FFU (Fan Filter Unit) as the core air supply device, matched with frames, isolation curtains and return air structures, it quickly forms a local high-cleanliness working area inside an ordinary workshop or low-grade clean room. It requires no modification to the original building ceiling and air duct system. Different from laminar flow ceiling and HEPA air supply outlets supported by central air conditioning systems, it is ideal for scattered working stations that need flexible relocation.<\/p>","protected":false},"author":3,"featured_media":6694,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[92],"tags":[],"class_list":["post-6693","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/6693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/comments?post=6693"}],"version-history":[{"count":1,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/6693\/revisions"}],"predecessor-version":[{"id":6697,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/6693\/revisions\/6697"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media\/6694"}],"wp:attachment":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media?parent=6693"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/categories?post=6693"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/tags?post=6693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}