{"id":5694,"date":"2026-07-31T09:54:34","date_gmt":"2026-07-31T01:54:34","guid":{"rendered":"https:\/\/www.bacintl.com\/?p=5694"},"modified":"2026-07-31T09:09:47","modified_gmt":"2026-07-31T01:09:47","slug":"ultra-clean-workbench-comprehensive-introduction-detailed-explanation-of-the-essential-local-purification-equipment-for-laboratories","status":"publish","type":"post","link":"https:\/\/www.bacintl.com\/es\/ultra-clean-workbench-comprehensive-introduction-detailed-explanation-of-the-essential-local-purification-equipment-for-laboratories\/","title":{"rendered":"Ultra-clean workbench comprehensive introduction | Detailed explanation of the essential local purification equipment for laboratories"},"content":{"rendered":"<p>I. Overview of Clean Bench<br \/>\nThe Clean Bench is the most commonly used single-person\/double-person local clean equipment in laboratories, medical fields, biology, food, electronics industries. The equipment forms a stable 100-level (ISO5) clean operating environment on the countertop through built-in fans and multi-stage filtration systems. It can effectively filter dust, bacteria, and particles in the air, providing a dust-free and sterile operating space for precise operations, aseptic experiments, and sample preparation.<br \/>\nCompared to laminar flow hoods and clean enclosures, the Clean Bench is smaller in size, plug-and-play, has a lower price, and does not require the renovation of the workshop. It is the preferred equipment for lightweight local purification.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-large wp-image-5697\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1400x787.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1000x562.jpg 1000w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><br \/>\nII. Working Principle<br \/>\nThe indoor air is sucked into the cabinet by the fan, pre-filtered by the G4 primary filter, and then purified by the HEPA high-efficiency filter at the end. The air is evenly sent out in parallel laminar flow through the equalizing membrane.<br \/>\nThe single-direction laminar airflow continuously replaces the air on the countertop, preventing external pollutants from entering the working area, and maintaining the ISO5 level of cleanliness in the operation area for a long time.<br \/>\nStandard air velocity: 0.35\u20130.55m\/s<br \/>\nCleanliness level: 100-level (Class 100 \/ ISO5)<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-large wp-image-5696\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-1400x787.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-1-1-1000x562.jpg 1000w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><br \/>\nIII. Equipment Structure Composition<br \/>\nCabinet shell: Cold-rolled steel plate electrostatic powder coating \/ 100% 304 stainless steel, corrosion-resistant and easy to clean.<br \/>\nHigh-efficiency filter: H13\/H14 grade glass fiber high-efficiency filter, core purification component.<br \/>\nPrimary filter: Pre-protection to extend the life of the high-efficiency filter.<br \/>\nLow-noise fan system: Provides stable pressure and uniform air volume.<br \/>\nEqualizing membrane: Stable pressure equalization, eliminating turbulent vortex.<br \/>\nIntelligent control system: Fan speed adjustment, ultraviolet sterilization, lighting, and timing functions.<br \/>\nTempered glass window: Transparent, dust-proof, and impact-resistant.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-large wp-image-5698\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-1400x787.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-2-1000x562.jpg 1000w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><br \/>\nIV. Two types of Clean BENCH<br \/>\n1. Vertical flow Clean Bench (mainstream in biology, medicine, and pharmaceuticals)<br \/>\nAir flows vertically downward from above<br \/>\nAdvantages: Does not directly blow towards personnel, high safety, stable aseptic effect, suitable for bacterial strains, cells, and aseptic operations.<br \/>\n2. Horizontal flow Clean Bench (mainstream in electronics and precision assembly)<br \/>\nAir flows horizontally from the back to the front<br \/>\nAdvantages: Uniform air volume, higher countertop cleanliness, suitable for electronic chips, optics, and precision components.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-large wp-image-5699\" src=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-1400x787.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-1400x787.jpg 1400w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-767x431.jpg 767w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-350x197.jpg 350w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-768x431.jpg 768w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-18x10.jpg 18w, https:\/\/www.bacintl.com\/wp-content\/uploads\/2026\/07\/\u8d85\u51c0\u5de5\u4f5c\u53f0\u4ecb\u7ecd-3-1000x562.jpg 1000w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><br \/>\nV. Main Application Domains<br \/>\n\u2705 Biological laboratories, microbial detection, cell culture<br \/>\n\u2705 Hospital laboratory departments, aseptic drug preparation<br \/>\n\u2705 Food, cosmetics aseptic testing<br \/>\n\u2705 Electronics, semiconductors, optical precision assembly<br \/>\n\u2705 Plant tissue culture, seedling inoculation<\/p>","protected":false},"excerpt":{"rendered":"<p>I. Overview of Clean Bench The Clean Bench is the most commonly used single-person\/double-person local clean equipment in laboratories, medical fields, biology, food, electronics industries. The equipment forms a stable 100-level (ISO5) clean operating environment on the countertop through built-in fans and multi-stage filtration systems. It can effectively filter dust, bacteria, and particles in the [&hellip;]<\/p>","protected":false},"author":3,"featured_media":5697,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[92],"tags":[],"class_list":["post-5694","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/5694","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/comments?post=5694"}],"version-history":[{"count":1,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/5694\/revisions"}],"predecessor-version":[{"id":5700,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/5694\/revisions\/5700"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media\/5697"}],"wp:attachment":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media?parent=5694"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/categories?post=5694"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/tags?post=5694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}