{"id":4982,"date":"2025-12-30T12:58:15","date_gmt":"2025-12-30T04:58:15","guid":{"rendered":"https:\/\/www.bacintl.com\/?p=4982"},"modified":"2025-12-30T08:55:19","modified_gmt":"2025-12-30T00:55:19","slug":"daily-operation-and-maintenance-of-the-automatic-double-opening-air-shower","status":"publish","type":"post","link":"https:\/\/www.bacintl.com\/es\/daily-operation-and-maintenance-of-the-automatic-double-opening-air-shower\/","title":{"rendered":"Daily operation and maintenance of the automatic double-opening air shower"},"content":{"rendered":"<p>Daily Operation and Maintenance Manual for Automatic Double-Opening Air Shower<br \/>\nI. Daily Operation Specifications (Implemented Daily)<br \/>\nCheck before startup<br \/>\nConfirm that the power supply and compressed air are normal (air pressure 0.4-0.6MPa);<br \/>\nCheck the door body&#8217;s sensing sensitivity and interlocking function (both doors cannot be opened simultaneously).<br \/>\nObserve that there is no abnormal noise during the operation of the fan and the air output from the nozzles is uniform.<br \/>\nUse the operation process<br \/>\nThe goods are pushed into the material shower room. After the sensor door closes automatically, the shower starts (the duration can be adjusted from 10 to 30 seconds).<br \/>\nThe goods should be placed evenly to avoid blocking the nozzles and sensing probes.<br \/>\nAfter the sprinkler is over, unlock the other side door before pushing out the goods. It is strictly prohibited to force the door open.<br \/>\nIn-operation monitoring<br \/>\nObserve the operation status of the equipment in real time. If there is a door jamming or spray fault, stop the machine immediately for inspection.<br \/>\nRecord the operation duration and the number of faults to form a daily operation ledger.<br \/>\nIi. Key Points of Daily Maintenance (Executed Weekly)<br \/>\nCleaning and maintenance<br \/>\nWipe the interior of the box, the glass of the door body and the sensor probe (avoid oil stains blocking).<br \/>\nClear foreign objects from the nozzle, ensure smooth air flow, and use compressed air to blow away the floating dust on the surface of the filter screen.<br \/>\nFunction check<br \/>\nTest the reliability of the interlock of the door body and the induction switch, and adjust the induction distance (it is recommended to be 50-100cm).<br \/>\nCheck whether the sealing strip is intact. If any damage is found, replace it in time (to prevent leakage in the clean area).<br \/>\nVerify the setting of the spray duration to ensure it meets the requirements of the clean area.<br \/>\nSafety inspection<br \/>\nCheck whether the power cord and terminal blocks are loose or aged, and whether the grounding is reliable.<br \/>\nClear away any debris around the equipment, ensure good ventilation and avoid blocking the heat dissipation ports.<br \/>\nIii. Regular Maintenance Plan (Executed Periodically)<\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 196px;\" border=\"1\">\n<tbody>\n<tr style=\"height: 52px;\">\n<td style=\"width: 33.3333%; height: 52px;\">\n<p>Cycle<\/p>\n<\/td>\n<td style=\"width: 33.3333%; height: 52px;\">Maintenance items<\/td>\n<td style=\"width: 33.3333%; height: 52px;\">Operating standards<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 33.3333%; height: 48px;\">Every month<\/td>\n<td style=\"width: 33.3333%; height: 48px;\">Cleaning\/replacement of the primary filter<\/td>\n<td style=\"width: 33.3333%; height: 48px;\">Replace when the pressure difference is greater than 200Pa. After cleaning, it needs to be dried before being reinstalled<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 33.3333%; height: 24px;\">Every three months<\/td>\n<td style=\"width: 33.3333%; height: 24px;\">Lubrication of fan bearings<\/td>\n<td style=\"width: 33.3333%; height: 24px;\">Add lithium-based grease to ensure smooth operation<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 33.3333%; height: 48px;\">Every six months<\/td>\n<td style=\"width: 33.3333%; height: 48px;\">Detection of High-efficiency filters<\/td>\n<td style=\"width: 33.3333%; height: 48px;\">Replace when the filtration efficiency is less than 99.99%, as detected by a dust particle counter<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 33.3333%; height: 24px;\">Every year<\/td>\n<td style=\"width: 33.3333%; height: 24px;\">Comprehensive maintenance<\/td>\n<td style=\"width: 33.3333%; height: 24px;\">Inspect the motor and electrical control system, calibrate the sensing elements, and replace the aged parts<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Iv. Common Fault Handling<br \/>\nThe door cannot open automatically: Check if the sensor probe is blocked \u2192 Confirm if the interlock function is normal \u2192 Investigate the pressure of the compressed air.<br \/>\nSpray not starting: Check if the fan is running \u2192 Clean the clogged nozzle \u2192 Check the fuse in the control circuit.<br \/>\nExcessive operating noise: Tighten the fixing bolts of the fan \u2192 Check the wear of the bearings \u2192 Clean the accumulated dust on the fan impeller.<br \/>\nThe pressure difference in the clean area is normal: Check if the sealing strip is damaged \u2192 Replace the clogged filter \u2192 Check if the door body is tightly closed.<br \/>\nV. Safety Precautions<br \/>\nWhen maintaining, power and gas must be cut off, and a &#8220;Under Maintenance&#8221; sign should be hung. It is strictly prohibited to operate with power on.<br \/>\nWhen replacing the filter, it should be operated on the clean area side to avoid contaminating the high-efficiency filter.<br \/>\nIt is strictly prohibited to forcibly push in oversized or overweight goods to avoid damaging the door body and guide rails (the rated load capacity must comply with the equipment parameters).<br \/>\nOperators must be trained before taking up their posts and strictly abide by the operating procedures. It is prohibited to modify parameters without authorization.<\/p>","protected":false},"excerpt":{"rendered":"<p>Daily Operation and Maintenance Manual for Automatic Double-Opening Air Shower I. Daily Operation Specifications (Implemented Daily) Check before startup Confirm that the power supply and compressed air are normal (air pressure 0.4-0.6MPa); Check the door body&#8217;s sensing sensitivity and interlocking function (both doors cannot be opened simultaneously). Observe that there is no abnormal noise during [&hellip;]<\/p>","protected":false},"author":3,"featured_media":4983,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[92],"tags":[],"class_list":["post-4982","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-technology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/4982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/comments?post=4982"}],"version-history":[{"count":2,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/4982\/revisions"}],"predecessor-version":[{"id":4985,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/posts\/4982\/revisions\/4985"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media\/4983"}],"wp:attachment":[{"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/media?parent=4982"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/categories?post=4982"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bacintl.com\/es\/wp-json\/wp\/v2\/tags?post=4982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}